Level Transmitters
FMP 45 Guided Wave Radar
SMART TRANSMITTER FOR:
- Level Measurement in Liquids
- Interface Measurement in Liquids
BENEFITS:
- Measurement independent of product properties as:
- density,
- dielectric constant,
- conductivity.
- Measurement is also possible in the event of foam or if the surface is very turbulent.
- Simple, menu-guided onsite operation with four-line plain text display.
- Easy remote operation, diagnosis and measuring point documentation with the free operating program supplied.
- Optional remote display and operation.
- Onsite envelope curve on the display for easy diagnosis.
- Electronics can be replaced without opening the tank.
- Application in safety related systems (overspill protection) with requirements for functional safety up to SIL 2 in accordance with IEC 61508/IEC 61511-1.
- Approvals:
- Europe: ATEX, WHG.
- North America: FM, CSA, boiler act.

Click HERE to download Bridle Specification Guide
|
|
Level measurement:
The Levelflex M is used for continuous level measurement of liquids.
FMP45 for highest of pressures and/or temperatures.
- Temperature range:
-200 °C (-328 °F) ... +400 °C (+752 °F)
- Pressure range: -1 ... 400 bar (5802 psi)
- With second safety compartment: gas-tight glass feed through
- Rod and coax probes up to 4 m (157"), rope probes up to 35 m (1378") measuring range
The following interfaces are available for system integration:
- HART (standard) with 4...20 mA analog,
- PROFIBUS PA,
- FOUNDATION Fieldbus.
|
Interface measurement
Continuous measurement of interfaces between two liquids with very different dielectric constants, such as in the case of oil and water.
- Measurement independent of density, conductivity and temperature
- Electronics version for the simultaneous measurement of the level of interfaces and the total level in liquids. The HART with 4 to 20 mA analog protocol is available for system integration
- Special version for the measurement of the level of interfaces at a constant total level. The PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration.
|
Measuring range |
- up to 4 m / 13 ft
(Rod probe)
- up to 35 m / 114 ft
(Rope probe)
|
Dielectric constant |
- 1.6 (Rope probe, Rod probe)
- 1.4 (Coax probe)
|
Temperature |
- -200...400 °C / -328...752 °C
|
Probes: |
- Rod probe
- Coax probe
- Rope probe
|
Pressure |
- -1...400 bar / ...5800 psi
|
|
|