Level Transmitters

VEGAPULS 60 Series Guided Microwave Radar

Level Measurement Transmitters for:

VEGAPULS 60 SERIES
VEGAFLEX 61
VEGAFLEX 65
VEGAFLEX 66

BENEFITS:

  • Process connections from 3/4" NPT and flanges from 1" ANSI
  • Measurement ranges with cable probe up to 32 m
  • Measurement ranges with rod probe up to 6 m
  • Measurement ranges with coax probe up to 6 m
  • Simple setup with adjustment
    Local PLICSCOM indication and programming module
  • No recalibration required
  • Detachable rod and cable probes for easy replacement
  • Two-wire, loop-powered
  • Insensitive to vapor, dust, condensation, or buildup
  • FM, CSA, WHG, and ATEX approvals

LEVEL MEASUREMENT:

  • Continuous level measurement of liquids and powdery to granular bulk solids
  • Reliable measurement in process temperatures up to 400°C and
    pressures up to 400 bar with the VEGAFLEX 66
  • Measurement in the presence of foam or agitation
  • 4-20 mA HART®, Foundation Fieldbus®, and Profibus PA outputs available
  • SIL2 Qualified (IEC 61508/61511 Standards)

Click HERE to download Bridle Specification Guide

VEGAPULS 60 Applications *********** INCOMPLETE

Level measurement:
Continuous level measurement of powdery to granular bulk solids e.g. plastic granulate and liquids.

  • Measurement independent of density or bulk weight, conductivity, dielectric constant, temperature and dust e.g. during pneumatic filling.
  • Measurement is also possible in the event of foam or if the surface is very turbulent.
  • The HART with 4 to 20 mA analog, PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration.
  • Application in safety related systems (overspill protection) with requirements for functional safety up to SIL 2 in accordance with IEC 61508/IEC 61511-1.
  • WHG approval

Interface measurement

  • Continuous measurement of interfaces between two liquids with very different dielectric constants, such as in the case of oil and water for example.
  • Measurement independent of density, conductivity and temperature
  • Electronics version for the simultaneous measurement of the level of interfaces and the total level in liquids. The HART with 4 to 20 mA analog protocol is available for system integration.
  • Special version for the measurement of the level of interfaces at a constant total level. The PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration

 

 

VEGAPULS 60 Specifications ******INCOMPLETE
Measuring range
  • up to 4 m / 13 ft (Rod probe, Coax probe) up to 35m / 114 ft (Rope probe)
Dielectric constant
  • 1.6 (Rod probe, Rope probe)
  • 1.4 (Coax probe)
Temperature
  • -40...150 °C / -40...302 °F
Probes:
  • Rod probe
  • Coax probe
  • Rope probe
Pressure
  • -1...40 bar / ...580 psi
   

 

Home | About Us | Products | Services | Software | Contact Us