Level Transmitters
VEGAPULS 60 Series Guided Microwave Radar
Level Measurement Transmitters for:
- Liquids (VEGAFLEX 61, 65, and 66)
- Light Bulk Solids (VEGAFLEX 61, 66)
- High Temperature and Pressure Applications (VEGAFLEX 66)
BENEFITS:
- Process connections from 3/4" NPT and flanges from 1" ANSI
- Measurement ranges with cable probe up to 32 m
- Measurement ranges with rod probe up to 6 m
- Measurement ranges with coax probe up to 6 m
- Simple setup with adjustment
Local PLICSCOM indication and programming module
- No recalibration required
- Detachable rod and cable probes for easy replacement
- Two-wire, loop-powered
- Insensitive to vapor, dust, condensation, or buildup
- FM, CSA, WHG, and ATEX approvals
LEVEL MEASUREMENT:
- Continuous level measurement of liquids and powdery to granular bulk solids
- Reliable measurement in process temperatures up to 400°C and
pressures up to 400 bar with the VEGAFLEX 66
- Measurement in the presence of foam or agitation
- 4-20 mA HART®, Foundation Fieldbus®, and Profibus PA outputs available
- SIL2 Qualified (IEC 61508/61511 Standards)

Click HERE to download Bridle Specification Guide |
|
|
|
Level measurement:
Continuous level measurement of powdery to granular bulk solids e.g. plastic granulate and liquids.
- Measurement independent of density or bulk weight, conductivity, dielectric constant, temperature and dust e.g. during pneumatic filling.
- Measurement is also possible in the event of foam or if the surface is very turbulent.
- The HART with 4 to 20 mA analog, PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration.
- Application in safety related systems (overspill protection) with requirements for functional safety up to SIL 2 in accordance with IEC 61508/IEC 61511-1.
- WHG approval
|
Interface measurement
- Continuous measurement of interfaces between two liquids with very different dielectric constants, such as in the case of oil and water for example.
- Measurement independent of density, conductivity and temperature
- Electronics version for the simultaneous measurement of the level of interfaces and the total level in liquids. The HART with 4 to 20 mA analog protocol is available for system integration.
- Special version for the measurement of the level of interfaces at a constant total level. The PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration
|
Measuring range |
- up to 4 m / 13 ft
(Rod probe, Coax probe)
up to 35m / 114 ft
(Rope probe)
|
Dielectric constant |
- 1.6 (Rod probe, Rope probe)
- 1.4 (Coax probe)
|
Temperature |
- -40...150 °C / -40...302 °F
|
Probes: |
- Rod probe
- Coax probe
- Rope probe
|
Pressure |
|
|
|