Level Output
Measured Variable |
Product Level/Interface Level |
Output |
4-20mA, HART |
Full Range |
Rigid Sensors: up to 10668 mm (420 in.) |
Non-linearity |
Rigid Sensors Element: 0.20% F.S. (Independent BSL) or 0.794 mm (1/32 in.) |
Repeatability |
0.001% of full span |
Sensor Operating Temperature |
-100°C (-150°F) to 121°C (250°F)** |
Gauge Loop
Input Voltage Range |
12-30 VDC, 24 VDC Nominal |
Reverse Polarity Protection |
Series diode |
Calibration
Zero Adjust Range |
Anywhere within the active length |
Span Adjust Range |
Full Scale ≥ 152 mm (6 in.) from zero |
Temperature Ratings
Electronics |
-40° C (-40° F) to 70° C (160°F) |
LCD Readout |
-40° C (-40° F) to 70° C (160°F) |
Standard |
-40° C (-40° F) to 114° C (235°F) |
HT Version |
-40° C (-40° F) to 214° C (400°F) |
Environmental
Humidity |
0 to 99.00%, non-condensing |
Materials (non-wetted parts) |
316 stainless steel, CPVC, Hastelloy, Alloy 20 |
Field Installation
Mounting |
NPT fitting (3/4 in. rigid, 1 in. flex) |
Wiring |
2- wire connection, shielded cable or twisted pair to screw terminals through a 1/2 in. NPT conduit opening NEMA Type 4X: 15ft (457 cm) pigtail integral cable or Daniel Woodhead (Part No. 70807SS) 6 – pin Male 1/4 in. -18MNPT key-way receptacle, 3/4 in. NPT conduit opening of Ex housing |
Display (Optional)
Measured Variables |
Level 1, Level 2 |
Update Rate |
3 Seconds |
Size |
12.7mm (0.5 in) |
Number of Digits |
8 |
HART Communications
Method of Communication |
Frequency Shift Keying (FSK) conforms with Bell 202 Modem
Standard with respect to baud rate and digital “1” and “0” frequencies |
Data Byte Structure |
1 Start bit, 8 Data bits, 1 Odd Parity bit, 1 Stop bit |
Digital Process Variable Rate |
Poll/Response Model 2.0 per second |
Agency Approvals
FM (Canada & US)
Intrinsically Safe
Class I, Division 1 :
Groups A, B, C, D
Class II, Division 1 :
Groups E, F, G Class III,
NEMA Type 4X
Explosion-Proof
Class I, Division 1 :
Groups B, C, & D
Class II, Division 1 :
Groups E, F, G
NEMA Type 4X