Level-Trac products include water columns and probes capable of operating in applications up to 3000 PSI as well as broad line of Water Detection Control Units & Alarms.
Level-Trac LT-500
Low Pressure Probe Manifold
- Max 1000 PSI
- SA-105 Extruded Chamber
- Horizontal Probe Mounting
- Probe Spacing per Customer’s Requirements
- Optional Connections for Direct Reading Sight Glasses
- Type 800, TFE Insulated Probe
- Piping Connections to Meet Customer Specifications
Level-Trac LT-501
Medium Pressure Probe Manifold
- Max 2000 PSI
- Extruded A-105 Column
- Probe Spacing per Customer’s Requirements
- Optional Connections for Direct Reading Sight Glasses
- Piping Connections to Meet Customer Specifications
- Type 810, Zirconia Insulated Probe
- Piping Connections to Meet Customer Specifications
Level-Trac LT-502
Medium Pressure Probe Manifold
- Max 3000 PSI
- 2” Schedule 160, A-106B Chamber
- Level-Lock Fittings that Ensure Full Penetration Welds
- Probe Spacing per Customer Requirements
- Optional Connections for Direct Reading Sight Glasses
- Type 820Â Probes
- Piping Connections to Meet Customer Specifications
Level-Trac LT-40 / LT-41
Point Level Switch
- LT-40-01: One Type 800, TFE insulated probe, rated to 1000 PSI
- LT-40-02: Two Type 800, TFE insulated probes, rated to 1000 PSI
- LT-41-01: One Type 810, Zirconia insulated, brazed probe, rated to 2000 PSI
- LT-41-02: Two Type 810, Zirconia insulated, brazed probes, rated to 2000 PSI
Level-Trac LT-210
Electronic Control Unit
- One to Twelve Probe Channels
- 4-20mA Output Signal
- Field Programmable Alarm and Trip Points
- Voting Logic for Trips
- Serial Remote Display Signal
- Sequence Fault Detection
- Single Power Supply
Level-Trac LT-230
Electronic Control Unit
- Up to 36 Probe Channels
- 4-20mA Output Signal
- Programmable Alarm and Trip Points
- Voting Logic for Trips
- Serial Remote Display Signal
- Sequence Fault Detection
- LED Display on unit (optional)
Level-Trac LT-420
Control Unit for Guided Wave Radar
- 4-20mA Output Signal
- Programmable Alarm & Trip Points from Guided Wave Radar
- Serial Remote Display Signal – Optional Fiber Optic
- Ability to power three remote indicators
- 4 – Relays, 8 AMP per relay
- ASME PG60.1.1.2 Code Compliant
Level-Trac LT-310
Electronic Control Unit
- Six Discrete Channels
- Six Field Assignable Auxiliary Relays
- Two Independent Power Supply Units
- Probe Cable Fault Monitoring
- No Maintenance or Routine Testing
- Fault Detection
Level-Trac LT-440
Control Unit for Guided Wave Radar
- NEMA 4X Fiberglass Reinforced Polyester Enclosure
- 100-240 VAC 48-63 Hz Power Supply
- Data Collected from (4) Thermocouple inputs to correct water density error.
- Loop input for drum temperature
- System Fault Logic and Indication
- Low Power Consumption, 0.25 Amp Maximum
Alarm and Trip Logic
- Four DPDT relays for alarm and trip actuation
- Dedicated DPDT relay to be programmed and used as the application requires
Door mounted indicator Fault Logic
- Illuminate if a thermocouple zeros or exceeds a given set point
- any individual thermocouple that indicates a failure will be ignored when estimating water temperature
Level-Trac Model LT-302
Control Unit
- NEMA 4X Fiberglass Reinforced Polyester Enclosure
- 100-240 VAC 48-63 Hz Power Supply
- Low Voltage (5 VAC) to probes
- Voting Logic Controlled Trip Circuits
- System Fault Logic and Indication
- Circuit Test Buttons
- Adjustable Time Delay
- Three Ranges of Sensitivity
- Low Power Consumption, 0.12 Amp Maximum