System Design
| Measurement Principle | Guided time-of-flight via time domain reflectometry |
|---|
Input
| Measurement Variable | Level, determined by the time-of-flight of a guided radar pulse from transmitter to product surface and back |
|---|
| Zero and Span | 6 inches to 75 feet ( 15 to 2286 cm) |
|---|
User Interface
| Keypad | 3-button menu-driven data entry and system security |
|---|
| Indication | 2-line x 8-character display |
|---|
| Digital Communication | HART, Fieldbus |
|---|
| Minimum Operating Voltage | 9 VDC |
|---|
| Quiescent Current Draw | 15 mA |
|---|
| DEV Revision | 0X01 |
|---|
| Function Blocks | Al_1, Al_2, Al_3, Al_4 |
|---|
| Damping | Adjustable 0-10 seconds |
|---|
Power
(Measured at instrument terminals)
| General Purpose / Explosion Proof | 9 to 32 VDC ( 15 mA maximum current draw) |
|---|
| IS/FISCO/FNICO | 9 to 32 VDC ( 15 mA maximum current draw) |
|---|
Housing
| Material | Aluminum A356T6 (<0.20% copper), optional 316 SST |
|---|
| Cable Entry | ¾” NPT and M20 |
|---|
Environment
| Operating Temperature | -196 to +842°F (-320 to +450°C) Model Dependent |
|---|
| Pressure | Vacuum -14.5 to 5,800psi (Vacuum -1 to +400bar) Model Dependent |
|---|
| Display Function Operating Temperature | -5 to +160°F (-20 to +70°C) |
|---|
| Storage Temperature | -50 to +175°F (-40 to +80°C) |
|---|
| Humidity | 0-99%, non-condensing |
|---|
| Electromagnetic Compatibility | Meets CE Requirements: EN 50081-2, EN 50082-2 |
|---|
| Shock Class | ANSI/ISA-S71.03 Class SA1 |
|---|
| Vibration Class | ANSI/ISA0S71.03 Class VC2 |
|---|
| Reference Conditions | Reflection from water +70°F (+20°C) with 72” coaxial probe (CFD threshold) |
|---|
| Linearity | Coaxial/Twin Rod Probes: | <0.1% of probe length or 0.1 inch (whichever is greater) |
|---|
| Single Rod Probes: | <0.3% of probe length or 0.3 inch (whichever is greater) |
| Measured Error | Coaxial/Twin Rod Probes: | ±0.1% of probe length or 0.1 inch (whichever is greater) |
|---|
| Single Rod Probes: | ±0.5% of probe length or 0.5 inch (whichever is greater) |
| Resolution | ±0.1 inch |
|---|
| Repeatability | <0.1 Inch |
|---|
| Hysteresis | <0.1 Inch |
|---|
| Response Time | <1 second |
|---|
| Warm-up Time | <5 seconds |
|---|
| Operating Temp. Range | -40° to +175°F (-40° to +80°C) |
|---|
| LCD Temp. Range | -5° to +160°F (-20° to +70°C) |
|---|
| Ambient Temp. Effect | Approximately +0.02% of probe length/ °C |
|---|
| Process Dielectric Effect | <0.3 inch within select range |
|---|
| Humidity | 0-99%, non-condensing |
|---|
| Electromagnetic Compatibility | Meets CE Requirements (EN-61000-6-2/2001, 61000-6-4/2001) |
|---|